📍 UC HEALTH — 3200 BURNET AVE, CINCINNATI OH, 45229
Jun 19, 2025 → Oct 29, 2025
✅ Completed
PC
SLA Clock
Per client agreement · Target: Jan 31, 2026
✓ SLA Met (61 biz days early)
Active: 0 biz days
Paused: 91 biz days
🕐 Clock stopped: Completed (Oct 29, 2025)
▶ Clock Running
Status: Created
Jun 19 → Jun 19, 2025
0 business days (counted)
Running total: 0 of ? biz days used
⏸91d
⏸ Clock Paused
Status: Ready for Release
Jun 19 → Oct 29, 2025
91 business days (not counted)
▶ Clock Running
Status: Scheduled
Oct 29 → Oct 29, 2025
0 business days (counted)
Running total: 0 of ? biz days used
▶ Clock Running
Status: Tech On Site
Oct 29 → Oct 29, 2025
0 business days (counted)
Running total: 0 of ? biz days used
Created: Jun 19, 2025Completed: Oct 29, 2025
Show SLA Clock Detail (4 periods)
Period
Status
Clock
Biz Days
Running Total
Jun 19 → Jun 19
Created
▶ Running
0
0
Jun 19 → Oct 29
Ready for Release
⏸ Paused
91
—
Oct 29 → Oct 29
Scheduled
▶ Running
0
0
Oct 29 → Oct 29
Tech On Site
▶ Running
0
0
Holding91.0d (excluded)
Coordinators0.8d
Field Work0.1d
Billing3.0d
✓ SLA Met
Holding(excluded from total)
91.0 days
Coordinators
0.8 days
Field Work
0.1 days
Billing
3.0 days
Over SLA
Created: Jun 19, 2025
Due: Jan 31, 2026
Completed: Oct 29, 2025 (94 days early)
📅
91.0 daysTotal Age
⏱️
91.0d in Ready for ReleaseLongest Stage
🔄
7 transitionsStatus Changes
⚠️
3.2d overTotal Delay
📦
0 orders, 0 quotesParts & Quotes
📝
3 linesWork Details
🏠
1 visitOn-Site Trips
👤
Self-ScheduledScheduling
AI Analysis
Powered by OpenAI
Generating AI analysis...
Completed with minor delays
Invoiced • 258 days old
🚨
Primary Delay91.0 days stuck in "Ready for Release"
⏱️
Total Delay3.2 business days over SLA thresholds
SLA vs Actual Time by Status
Actual (within SLA)
Actual (over SLA)
SLA Target
Entered
0.0d / 0.5d SLA
Ready for Release
91.0d
Scheduled
0.8d / 2.0d SLA
Tech On Site
0.1d / 1.0d SLA
Closed
2.2d / 1.0d SLA
Ready to Bill
3.0d / 1.0d SLA
Invoice Pending
0.0d / 2.0d SLA
💬 Activities, Notes & Communications
🔒Internal CSA Notes
10/15/2025 rcvd call from Ann 414-368-6271. She is a GE rep tech support. she will reach out to FMI team for poc information.
10/15/2025 mklose called (513) 475-8000; xfer to BioMed. Ji confirmed this device is at UC Health 3200 Burnet Ave. Ticket # 1-556228130418. will send message and have engineer call us.
🔧Work Performed
"Template Name:
Template Description:
Problem Found:
Action Taken: Completed FMI 78101 by installing SW Version R4.5 and communicated with customer to scrap previous software versions.
Verification Test: Performed Probe and Connectors Checks for all probes. Confirmed all probes pass. Completed all Peripheral Checks-system passed. Completed full system diagnostics-system passed.
Equipment passed all required tests and has been returned to the customer fully functional.
Template Name:
Template Description:
Problem Found:
Action Taken: “Completed FMI 78101 by installing new supplied batteries / Batteries installed by
customer and dispose of old batteries according to local regulation”.
Verification Test: “Performed battery charging test - verified after 10 minutes, the scan time increased. Completed full system diagnostics-system passed. Equipment passed all required tests and has been returned to the customer fully functional”."
🔍Technician Findings
78101
⚠️Problem Description
FMI 78101E: Venue Fit Thermal Event due to battery Purpose: Each affected system will have a SW Version R4.4.3 update installed. FMI Type: Mandatory Recall FMI For code 2, 3, 4 and 5 closures, please reach out to FMI admin team at TCS.FMIAdmin@gehealthcare.com or 8668836784 – OPT. 5 for assistance in closing and correct objective evidence attachment to Activity/SR.
📄Description
GE Healthcare - Venue Fit Ultrasound
📞Call Description
FMI 78101
📞
Live Call_ Asked to Call Back
Completed Oct 15, 2025
10/15/2025 rcvd call from Ann 414-368-6271. She is a GE rep tech support. she will reach out to FMI team for poc information.
📞
Live Call_Confirmed Devices During Call
Completed Oct 15, 2025
10/15/2025 mklose called 513-475-8000; xfer to biomed. Ji. confirm device at UC Health 3590 Lucille Dr Ste 2500.ticket # 1-556227950758. will send message and have engineer call us.
📅
WO-01282049 - FCO - Venue Fit Ultrasound - CINCINNATI - UC HEALTH
Oct 28, 2025 8:00pm – 8:00pm
Work Order: WO-01282049
Account: GE Healthcare FMI
Customer Case Number: 1-554880556626, 1-554907991295
Location: UC HEALTH
Address: 3200 BURNET AVE, CINCINNATI, OH 45229
Manufacturer: GE Healthcare
Model #: Venue Fit Ultrasound
Serial #: VFD000983
Contact Name:
Contact Phone:
Contact Email:
Due
JPG
VFD000983 SERIAL #
Oct 29, 2025
JPG
VFD000983 BATTERY
Oct 29, 2025
PDF
VFD000983
Oct 29, 2025
JPG
VFD000983 SOFTWARE
Oct 29, 2025
JPG
VFD000983 WORKLIST
Oct 29, 2025
Timeline
📋
Work Order Created Jun 19, 2:27 PM
Work Order:WO-01282049
Type:FCO
Priority:PC
✅
Status: Ready for Release by Allison BelyeaJun 19, 3:12 PM