📍 KNOX COMMUNITY HOSPITAL — 1330 COSHOCTON AVE, MOUNT VERNON OH, 43050
Jun 19, 2025 → Nov 25, 2025
✅ Completed
PC
SLA Clock
Per client agreement · Target: Jan 31, 2026
✓ SLA Met (42 biz days early)
Active: 4 biz days
Paused: 106 biz days
🕐 Clock stopped: Completed (Nov 26, 2025)
▶ Clock Running
Status: Created
Jun 19 → Jun 19, 2025
0 business days (counted)
Running total: 0 of ? biz days used
⏸106d
⏸ Clock Paused
Status: Ready for Release
Jun 19 → Nov 20, 2025
106 business days (not counted)
▶ Clock Running
Status: Scheduled
Nov 20 → Nov 20, 2025
0 business days (counted)
Running total: 0 of ? biz days used
⏸ Clock Paused
Status: Awaiting Parts
Nov 20 → Nov 20, 2025
0 business days (not counted)
▶ Clock Running
Status: Scheduled
Nov 20 → Nov 25, 2025
3 business days (counted)
Running total: 3 of ? biz days used
▶ Clock Running
Status: Tech On Site
Nov 25 → Nov 26, 2025
1 business day (counted)
Running total: 4 of ? biz days used
Created: Jun 19, 2025Completed: Nov 26, 2025
Show SLA Clock Detail (6 periods)
Period
Status
Clock
Biz Days
Running Total
Jun 19 → Jun 19
Created
▶ Running
0
0
Jun 19 → Nov 20
Ready for Release
⏸ Paused
106
—
Nov 20 → Nov 20
Scheduled
▶ Running
0
0
Nov 20 → Nov 20
Awaiting Parts
⏸ Paused
0
—
Nov 20 → Nov 25
Scheduled
▶ Running
3
3
Nov 25 → Nov 26
Tech On Site
▶ Running
1
4
Material Management0.1d
Holding106.0d (excluded)
Coordinators3.9d
Field Work0.7d
Billing0.4d
✓ SLA Met
Material Management
0.1 days
Holding(excluded from total)
106.0 days
Coordinators
3.9 days
Over SLA
Field Work
0.7 days
Billing
0.4 days
Created: Jun 19, 2025
Due: Jan 31, 2026
Completed: Nov 26, 2025 (66 days early)
📅
109.0 daysTotal Age
⏱️
106.0d in Ready for ReleaseLongest Stage
🔄
10 transitionsStatus Changes
⚠️
2.9d overTotal Delay
📦
1 orders, 0 quotesParts & Quotes
📝
12 linesWork Details
🏠
2 visitsOn-Site Trips
👤
Self-ScheduledScheduling
🔄
2 On-Site Visits
2 on-site visits — follow-up trip required
👤 Self-scheduled by Eric Mancerella — scheduling delays attributed to technician, not coordinators
Visit 1Nov 24, 2025
Visit 2Nov 25, 2025
AI Analysis
Powered by OpenAI
Generating AI analysis...
Completed with minor delays
Invoiced • 258 days old
🚨
Primary Delay106.0 days stuck in "Ready for Release"
⏱️
Total Delay2.9 business days over SLA thresholds
SLA vs Actual Time by Status
Actual (within SLA)
Actual (over SLA)
SLA Target
Entered
0.0d / 0.5d SLA
Ready for Release
106.0d
Scheduled
3.9d / 2.0d SLA
Awaiting Parts
0.1d / 3.0d SLA
Tech On Site
0.7d / 1.0d SLA
Closed
2.0d / 1.0d SLA
Ready to Bill
0.4d / 1.0d SLA
Billing Review
0.0d / 2.0d SLA
💬 Activities, Notes & Communications
🔒Internal CSA Notes
11/19/2025 DMalloy - Planner Rich received call from customer confirmaing the device and he advised that the device was hardly used and we could come anytime for the remediations. Emailed customer advising that I can have FSE Eric onsite on next week Wednesday, 11/26/2025.
gregg.gebhardt@gehealthcare.com
11/18/2025 MHamersley - called 740-393-9000, xfer to Bio Med, call went to VM/LM
Venue Fit Ultrasound VFD001631
🔧Work Performed
"Template Name:
Template Description:
Problem Found:
Action Taken: Completed FMI 78101 by installing SW Version R4.5 and communicated with customer to scrap previous software versions.
Verification Test: Performed Probe and Connectors Checks for all probes. Confirmed all probes pass. Completed all Peripheral Checks-system passed. Completed full system diagnostics-system passed.
Equipment passed all required tests and has been returned to the customer fully functional.
Template Name:
Template Description:
Problem Found:
Action Taken: “Completed FMI 78101 by installing new supplied batteries / Batteries installed by
customer and dispose of old batteries according to local regulation”.
Verification Test: “Performed battery charging test - verified after 10 minutes, the scan time increased. Completed full system diagnostics-system passed. Equipment passed all required tests and has been returned to the customer fully functional”."
🔍Technician Findings
78101
⚠️Problem Description
FMI 78101E: Venue Fit Thermal Event due to battery Purpose: Each affected system will have a SW Version R4.4.3 update installed. FMI Type: Mandatory Recall FMI For code 2, 3, 4 and 5 closures, please reach out to FMI admin team at TCS.FMIAdmin@gehealthcare.com or 8668836784 – OPT. 5 for assistance in closing and correct objective evidence attachment to Activity/SR.
📄Description
GE Healthcare - Venue Fit Ultrasound
📞Call Description
FMI 78101
📞
Live Call_Left Message
Completed Nov 18, 2025
11/18/2025 MHamersley - called 740-393-9000, xfer to Bio Med, call went to VM/LM
📅
WO-01282095 - FCO - Venue Fit Ultrasound - MOUNT VERNON - KNOX COMMUNITY HOSPITAL
Nov 26, 2025 8:00am – 5:00pm
Work Order: WO-01282095
Account: GE Healthcare FMI
Customer Case Number: 1-554880527376, 1-554907961573
Location: KNOX COMMUNITY HOSPITAL
Address: 1330 COSHOCTON AVE, MOUNT VERNON, OH 43050
Manufacturer: GE Healthcare
Model #: Venue Fit Ultrasound
Serial #: VFD001631
Contact Name: Gregg Gebh
JPG
VFD001631 SERIAL #
Nov 25, 2025
PDF
VFD001631
Nov 25, 2025
JPG
VFD001631 BATTERY
Nov 25, 2025
JPG
VFD001631 NO WIFI CONNECTION
Nov 25, 2025
JPG
VFD001631 SHIPPING PAPER
Nov 25, 2025
JPG
VFD001631 NO WORKLIST OPTION
Nov 25, 2025
JPG
VFD001631 SOFTWARE
Nov 25, 2025
Timeline
📋
Work Order Created Jun 19, 2:27 PM
Work Order:WO-01282095
Type:FCO
Priority:PC
✅
Status: Ready for Release by Allison BelyeaJun 19, 3:15 PM