📍 CHILDRENS HOSPITAL OF SAN ANTONIO — 333 N SANTA ROSA ST, SAN ANTONIO TX, 78207
Sep 4, 2025 → Oct 14, 2025
✅ Completed
PC
SLA Clock
Per client agreement · Target: Oct 31, 2025
✓ SLA Met (12 biz days early)
Active: 20 biz days
Paused: 8 biz days
🕐 Clock stopped: Completed (Oct 15, 2025)
▶ Clock Running
Status: Created
Sep 4 → Sep 4, 2025
0 business days (counted)
Running total: 0 of ? biz days used
⏸3d
⏸ Clock Paused
Status: Ready for Release
Sep 4 → Sep 9, 2025
3 business days (not counted)
4d
▶ Clock Running
Status: Ready for Scheduling
Sep 9 → Sep 15, 2025
4 business days (counted)
Running total: 4 of ? biz days used
7d
▶ Clock Running
Status: Scheduled
Sep 15 → Sep 24, 2025
7 business days (counted)
Running total: 11 of ? biz days used
⏸5d
⏸ Clock Paused
Status: Ready for Release
Sep 24 → Oct 1, 2025
5 business days (not counted)
3d
▶ Clock Running
Status: Ready for Scheduling
Oct 1 → Oct 6, 2025
3 business days (counted)
Running total: 14 of ? biz days used
5d
▶ Clock Running
Status: Scheduled
Oct 6 → Oct 14, 2025
5 business days (counted)
Running total: 19 of ? biz days used
▶ Clock Running
Status: Tech On Site
Oct 14 → Oct 15, 2025
1 business day (counted)
Running total: 20 of ? biz days used
Created: Sep 4, 2025Completed: Oct 15, 2025
Show SLA Clock Detail (8 periods)
Period
Status
Clock
Biz Days
Running Total
Sep 4 → Sep 4
Created
▶ Running
0
0
Sep 4 → Sep 9
Ready for Release
⏸ Paused
3
—
Sep 9 → Sep 15
Ready for Scheduling
▶ Running
4
4
Sep 15 → Sep 24
Scheduled
▶ Running
7
11
Sep 24 → Oct 1
Ready for Release
⏸ Paused
5
—
Oct 1 → Oct 6
Ready for Scheduling
▶ Running
3
14
Oct 6 → Oct 14
Scheduled
▶ Running
5
19
Oct 14 → Oct 15
Tech On Site
▶ Running
1
20
Dispatch0.0d
Holding9.8d (excluded)
Coordinators21.8d
Field Work1.2d
Billing16.2d
✓ SLA Met
Dispatch
0.0 days
Holding(excluded from total)
9.8 days
Coordinators
21.8 days
Over SLA
Field Work
1.2 days
Over SLA
Billing
16.2 days
Over SLA
Created: Sep 4, 2025
Due: Oct 31, 2025
Completed: Oct 15, 2025 (16 days early)
📅
28.2 daysTotal Age
⏱️
14.0d in Ready to BillLongest Stage
🔄
14 transitionsStatus Changes
⚠️
29.9d overTotal Delay
📦
0 orders, 0 quotesParts & Quotes
📝
2 linesWork Details
🏠
1 visitOn-Site Trips
👤
Self-ScheduledScheduling
AI Analysis
Powered by OpenAI
Generating AI analysis...
Completed with significant delays
Invoiced • 181 days old
🚨
Primary Delay14.0 days stuck in "Ready to Bill"
⏱️
Total Delay29.9 business days over SLA thresholds
SLA vs Actual Time by Status
Actual (within SLA)
Actual (over SLA)
SLA Target
Entered
0.0d / 0.5d SLA
Ready for Release
9.8d
Ready for Scheduling
8.2d / 1.0d SLA
Scheduled
13.6d / 2.0d SLA
Tech On Site
1.2d / 1.0d SLA
Closed
2.0d / 1.0d SLA
07e-Partial Project
0.0d
Ready to Bill
15.0d / 1.0d SLA
Invoice Pending
1.2d / 2.0d SLA
💬 Activities, Notes & Communications
🔒Internal CSA Notes
10/06/2025 EMartin rcvd email from Jason advising device is located
NICU 56
replied advising FSE onsite 10/13/25 to complete devices
10/01/2025 MKlose rcvd email from Jason, confirm devices and locations ... 10/01/2025 Mklose called; 210.704.2145; VM for BioMed.... 09/24/2025 EMartin device needs located ... 09/15/2025 EMartin sent email to Jason.Johnson@intelashealth.com advising FSE onsite Monday 09/22/25 to complete devices 09/09/2025 MHamersley - recd email from Jason, confirming all devices still in active inventory; FSE Cred: FSE must scan their driver's license and print a visitor pass; ... 09/09/2025 MHamersley - called 210-385-0357, spoke to Jason Johnson, Dir Clinical Engineering; sent email: Jason.Johnson@intelashealth.com
🔧Work Performed
Template Name: FMI32097_Code 1_inspect.
Template Description: FMI32097_Code 1_inspect.
Problem Found: FMI32097_Heater door inspection.
Action Taken: FMI 32097 completed. Inspected the Heater doors
and confirmed screws tightened to the specification.
Verification Test:
1. Verified the canopy moves smoothly.
2. Verified transition mode message is not present.
3. Verified doors close smoothly.
4. Verified corner pins are aligned.
5. Verified no alarms.
The device has passed all tests and is ready for customer use
⚠️Problem Description
FMI 32097:- Inspection of heater door screws for Giraffe OmniBed and Giraffe OmniBed Carestation Purpose:- Certain Giraffe OmniBed and Giraffe OmniBed Carestation may have defective heater doors due to improper torquing of heater door screws. FMI Type: Mandatory Recall FMI For code 2, 3, 4 and 5 closures, please reach out to FMI admin team at tcs.fmiadmins@gehealthcare.com or 8668836784 – OPT. 5 for assistance in closing and correct objective evidence attachment to Activity/SR.
📄Description
GE Healthcare Giraffe OmniBed Carestation CS1
📞Call Description
FMI 32097
📅
WO-01301296 - FCO - Giraffe OmniBed Carestation - SAN ANTONIO - CHILDRENS HOSPITAL OF SAN ANTONIO
Oct 14, 2025 8:00am – 5:00pm
Work Order: WO-01301296
Account: GE Healthcare FMI
Customer Case Number: 1-555654004925
Location: CHILDRENS HOSPITAL OF SAN ANTONIO
Address: 333 N SANTA ROSA ST, SAN ANTONIO, TX 78207
Manufacturer:
Model #: Giraffe OmniBed Carestation
Serial #: TAB24050031SA
Contact Name: Jason Johnson, Dir
PDF
PF_32097_Childrens San Antonio_Signed
Sep 23, 2025
JPG
childrensSA1
Oct 14, 2025
JPG
childrensSA
Oct 14, 2025
JPG
childrensSA2
Oct 14, 2025
Timeline
📋
Work Order Created Sep 4, 9:33 AM
Work Order:WO-01301296
Type:FCO
Priority:PC
✅
Status: Ready for Release by Allison BelyeaSep 4, 9:55 AM
From:Entered
To:Ready for Release
Duration in Previous:22m
⏳4.0 business days
📅