Midmark Service Request Dispatch Authorization - WO-00105556
Closed
Travel Zone 2
PROBLEM SUMMARY
WD/02,04,05/07
ADDITIONAL NOTES
Please schedule for first thing tomorrow morning. Spoke with Melissa Owens and she has been made aware of this SR. Parts
are on site. Please schedule customer for first thing tomorrow morning. For assistance, troubleshooting, or parts identification,
contact Medical Tech Service at 844-856-1230. Thank you!
DISPATCH ITEMS
Serial # V2782617 Item 631-001
ITEM DESCRIPTION
631-001 PROCEDURE CHAIR NON-PROGRAMMABLE W/O TOP
PCR CODES
Problem Cause Resolution
BASE TILT FOOT NOT OPERATING
PROPERLY UM UNDETERMINED DIAGNOSING
PRODUCT
BACK FUNCTION NOT OPERATING
PROPERLY
WIRED CONTROLLER OR COMPONENT
FAULTY REPLACE PARTS
Problem Change Cause Change Resolution Change
PARTS
Service Activity Line Status Order Number Product Code Estimated
Qty
Actual
Qty Tracking Number
Ship Exchanged Completed 726316 002-10482-00 1.00000 1ZE444250175578793
9/18 MOwens Called to speak to William Kenny. Left vm for the scheduled visit for this morning.
09/17/2025 SRobinson- Per Midmark parts are onsite and to contact the customer first thing tomorrow morning to schedule.
🔧Work Performed
the foot rest is in the down position but is past the 90 degree position which triggered the safety system. The actuator plunger was not properly locked in place with a locking washer and the plunger was able to back out of its position allowing the footrest to go past the 90 degree. the plunger was position properly and the locking nut and washer were tightened.
🔍Technician Findings
WD/ error codes 02,04,05/07 BASE TILT FOOT NOT OPERATING
PROPERLY UM UNDETERMINED DIAGNOSING
PRODUCT
BACK FUNCTION NOT OPERATING
PROPERLY
WIRED CONTROLLER OR COMPONENT
FAULTY REPLACE PARTS
⚠️Problem Description
Travel Zone 2
PROBLEM SUMMARY
WD/02,04,05/07
ADDITIONAL NOTES
Please schedule for first thing tomorrow morning. Spoke with Melissa Owens and she has been made aware of this SR. Parts
are on site. Please schedule customer for first thing tomorrow morning. For assistance, troubleshooting, or parts identification,
contact Medical Tech Service at 844-856-1230. Thank you!
DISPATCH ITEMS
Serial # V2782617 Item 631-001
ITEM DESCRIPTION
631-001 PROCEDURE CHAIR NON-PROGRAMMABLE W/O TOP
PCR CODES
Problem Cause Resolution
BASE TILT FOOT NOT OPERATING
PROPERLY UM UNDETERMINED DIAGNOSING
PRODUCT
BACK FUNCTION NOT OPERATING
PROPERLY
WIRED CONTROLLER OR COMPONENT
FAULTY REPLACE PARTS
Problem Change Cause Change Resolution Change
PARTS
Service Activity Line Status Order Number Product Code Estimated
Qty
Actual
Qty Tracking Number
Ship Exchanged Completed 726316 002-10482-00 1.00000 1ZE444250175578793
📄Description
Midmark Model: 630 (Series) Human Form Procedures Chair
📋
Outbound to +14103400039
Completed Sep 18, 2025
Called to speak to William Kenny. Left vm for the scheduled visit for this morning.
📞
Call
Completed Sep 17, 2025
09/17/2025 SRobinson- Per Midmark parts are onsite and to contact the customer first thing tomorrow morning to schedule.