Zone 1
Dispatch Type Repair
PROBLEM SUMMARY
WD / no base function 0204 error
ADDITIONAL NOTES
Part shipping UPS Next Day Air. For assistance, troubleshooting, or parts identification, contact Medical Tech Service at
844-856-1230. Thank you!
The delivery date will be provided as soon as possible.
2-16 Mburris spoke with Amanda O'Neill and set with other WO she wants both done together
2/16/26 RBerry- Sent teams message to ASC to reach out to customer to confirm if they are wanting this WO completed with WO-01349523 (scheduled).
2/15/26 RBerry- Updated due date based on parts.
2/13/2026jsells
Ship To Name: SVMF Sacramento Arden Care Center
Ship To Address: 1651 Exposition Blvd Ste 201
Ship To City/State: Sacramento, CA 95815-5149
Waybill (Tracking #): 1ZE444250170458501
Carrier: UPS-Air-Next Day Air
The following items have shipped from Midmark Corporation on: 13-FEB-2026
LINE NO: 1.1 QTY: 1 ITEM: 002-1747-00 SERIAL #: DESCRIPTION: KIT, SCP POWER SUPPLY PCB
2/13 KHardison, Spoke to Amanda regarding WO. Advised that a coordinator will call for scheduling.
🔧Work Performed
Installed replacement Power Supply PCB and successfully calibrated the exam chair. Performed functional testing and confirmed all chair movements, including base operation, are functioning normally. Demonstrated proper operation to the customer, Amanda O'Neill.
🔍Technician Findings
Arrived on site and verified base function was non-responsive. Customer supplied a replacement Power Supply PCB.
⚠️Problem Description
Zone 1
Dispatch Type Repair
PROBLEM SUMMARY
WD / no base function 0204 error
ADDITIONAL NOTES
Part shipping UPS Next Day Air. For assistance, troubleshooting, or parts identification, contact Medical Tech Service at
844-856-1230. Thank you!
📄Description
Midmark Model: 630 (Series) Human Form Procedures Chair
📋
Outbound to +12628759748
Completed Feb 16, 2026
2-16 Mburris spoke with Amanda O'Neill and set with other WO
📋
Outbound to +12628759748
Completed Feb 13, 2026
Spoke to Amanda regarding WO. Advised that a coordinator will call for scheduling.
📅
WO-01351679 - Repair - 630 (Series) - Sacramento - SVMF Sacramento Arden Care Center
Feb 18, 2026 1:00pm – 3:00pm
Work Order: WO-01351679
Account: MIDMARK
Customer Case Number: SR 1538692
Location: SVMF Sacramento Arden Care Center
Address: 1651 Exposition Blvd, Sacramento, CA 95815-5149
Manufacturer: Midmark Corp
Model #: 630 (Series)
Serial #: V2852150
Contact Name: Amanda O'Neill
Contact Phone: 262- 875-9748
PDF
00568276 SRA
Feb 13, 2026
PDF
00568276 SRA
Feb 18, 2026
Timeline
📞
Case Linked Feb 13, 12:15 PM
Case Number:00568276
Subject:Repair
Status:Closed
📋
▶
2
Work Order Created Feb 13, 3:17 PM
Work Order Created → Parts Added
🔩
Parts Added
Type:Parts
Status:Open
Qty:1
📅
Status: Ready for Scheduling by Kimberly HardisonFeb 13, 3:25 PM