Travel Zone 1
PROBLEM SUMMARY
NWD burning packs without error run with 1524428
ADDITIONAL NOTES
This dispatch needs to be completed on the same day as SR 1524428. Please ask for Myrna if Kaylen is not available to
schedule service. If part(s) are identified after speaking with Midmark Tech Service, the Service Company Tech must contact
the POC for authorization before ordering. Once approved, notify Midmark immediately. If more time is needed for the
customer’s decision to proceed, inform Midmark Dispatch at 937.688.9175 or dispatch@midmark.com. For assistance,
troubleshooting, or parts identification, contact Veterinary Tech Service at 844-856-1232, option 1. Thank you!
2-13 Mburris call set with Tony for 2-20 1pm asked for 2-20
2/9/2026 Sramen - updated wo status. Oracle shipment info shows:
updated due date and removed delay code.
1/27 ARios - Customer requested for us to come back on February 4th at 9am to continue troubleshooting unit.
1-22 Mburris called spoke with Kaylen Grutman and set 1-27 1pm
01/21/2026 SRobinson- Sent email to kgrutman@ethosvet.com and gave the WO# and advised a coordinator will be reaching out to schedule.
🔧Work Performed
1/27
Per Midmark technical support, I was advised to run a test cycle and monitor the unit for abnormalities or errors. The unit completed the initial test cycle without errors, however steam was observed leaking from the door. I discussed replacing the door gasket and running an additional test cycle with the customer and they approved. During the second test cycle, the unit generated error codes C983 and C980, indicating the high-limit thermostat remained open longer than expected. During a third test cycle, the unit generated error code C544, indicating sterilization steam temperature was too high. Midmark technical support was closed at the time, and a return visit will be required to continue troubleshooting.
2/04
Removed and cleaned the air valve. Unable to remove the vent valve for cleaning due to lack of a pin spanner wrench. During a test cycle, temperature reached 284°F and pressure reached 19 PSI before failing again with error C544. Water was observed leaking between the vent valve and the manifold block. A second test cycle confirmed the vent valve/manifold leak as the cause of the pressure loss and C544 error. Per the observed water leak, Midmark technical support recommended replacement of the fill/vent valve assembly and the fill tube. Unit has an old-style fill/vent valve assembly that will require replacement with the new-style assembly. The cooling fan runs continuously, indicating a failed fan control thermostat per Midmark technical support. Approval to purchase parts was confirmed with site manager Kaylen Grutman. Midmark will ship parts directly to the customer.
Fill / Vent Valve Assembly - 002-10017-00
Fan Control Thermostat - 015-1430-00
Fill Tube - 053-1033-05
2/20
Replaced all parts shipped, which consisted of the Fill/Vent Valve Assembly, Fan Control Thermostat, and Fill Tube. Encountered minor difficulty aligning the fill tube to the elbow at the bottom of the chamber, but the connection was successfully secured. Ran a test sterilization cycle which completed successfully without errors. Verified there are no visible leaks from the newly installed components.
🔍Technician Findings
1/27
Customer stated the unit has been in storage and unused for an extended period. Customer requested verification of operation and identification of any repairs needed to make the unit functional.
2/04
Arrived on site to continue troubleshooting unit.
2/20
Arrived on site and customer gave me parts to be replace on autoclave.
⚠️Problem Description
Travel Zone 1
PROBLEM SUMMARY
NWD burning packs without error run with 1524428
ADDITIONAL NOTES
This dispatch needs to be completed on the same day as SR 1524428. Please ask for Myrna if Kaylen is not available to
schedule service. If part(s) are identified after speaking with Midmark Tech Service, the Service Company Tech must contact
the POC for authorization before ordering. Once approved, notify Midmark immediately. If more time is needed for the
customer’s decision to proceed, inform Midmark Dispatch at 937.688.9175 or dispatch@midmark.com. For assistance,
troubleshooting, or parts identification, contact Veterinary Tech Service at 844-856-1232, option 1. Thank you!
📄Description
Midmark Model M11 (Series) Self Contained Steam Sterilizer (Includes ALL M11 Models)
📋
Outbound to +19162314445
Completed Feb 13, 2026
2-13 Mburris call set with Tony for 2-20 1pm
📧
Email: Update: Awaiting Parts for Your Work Order
Completed Feb 5, 2026
To: kgrutman@ethosvet.com
CC:
BCC:
Attachment: --none--
Subject: Update: Awaiting Parts for Your Work Order
Body:
Dear Customer,Thank you for choosing EMSAR for your service needs.We are currently awaiting the parts necessary to complete the work for your device.Work Order #: WO-01339189Location: Vista Veterinary SpecialistsAddress: 8299 E Stockton Blvd Sacramento, CA 95828-8200Device: M11 (Series) V371486Problem Description: Travel Zone 1