FMI 32097:- Inspection of heater door screws for Giraffe OmniBed and Giraffe OmniBed Carestation Purpose:- Certain Giraffe OmniBed and Giraffe OmniBed Carestation may have defective heater doors due to improper torquing of heater door screws. FMI Type: Mandatory Recall FMI For code 2, 3, 4 and 5 closures, please reach out to FMI admin team at tcs.fmiadmins@gehealthcare.com or 8668836784 – OPT. 5 for assistance in closing and correct objective evidence attachment to Activity/SR.
Primary Delay15.8 days stuck in "Ready for Release"
⏱️
Total Delay26.0 business days over SLA thresholds
SLA vs Actual Time by Status
Actual (within SLA)
Actual (over SLA)
SLA Target
Entered
5.3d / 0.5d SLA
Ready for Release
15.8d
Scheduled
12.0d / 2.0d SLA
Ready for Scheduling
2.2d / 1.0d SLA
Assigned
9.0d / 0.5d SLA
Tech On Site
1.0d / 1.0d SLA
Completed
0.0d / 1.0d SLA
Closed
5.0d / 1.0d SLA
💬 Activities, Notes & Communications
🔒Internal CSA Notes
02/06/2026 RFosbury dispatch to Ryan L
1/07/2026 RFosbury, called Matt Frank. Confirmed FSE onsite Jan 12th,13th, 14th
1/06/2026 RFosbury Called 434-465-0098 started to LVM but call disconnected. Sending FU email to uez6jg@uvahealth.org
🔧Work Performed
Template Name: FMI32097_Code 1_inspect.
Template Description: FMI32097_Code 1_inspect.
Problem Found: FMI32097_Heater door inspection.
Action Taken: FMI 32097 completed. Inspected the Heater doors and confirmed screws tightened to the specification.
Verification Test:
1. Verified the canopy moves smoothly.
2. Verified transition mode message is not present.
3. Verified doors close smoothly.
4. Verified corner pins are aligned.
5. Verified no alarms.
The device has passed all tests and is ready for customer use.
🔍Technician Findings
FMI STARTED
⚠️Problem Description
FMI 32097:- Inspection of heater door screws for Giraffe OmniBed and Giraffe OmniBed Carestation Purpose:- Certain Giraffe OmniBed and Giraffe OmniBed Carestation may have defective heater doors due to improper torquing of heater door screws. FMI Type: Mandatory Recall FMI For code 2, 3, 4 and 5 closures, please reach out to FMI admin team at tcs.fmiadmins@gehealthcare.com or 8668836784 – OPT. 5 for assistance in closing and correct objective evidence attachment to Activity/SR.
📄Description
GE Healthcare Giraffe OmniBed Carestation CS1
📞Call Description
FMI 32097
📅
WO-01324678 - FCO - Giraffe OmniBed Carestation - CHARLOTTESVILLE - UNIVERSITY OF VIRGINIA HEALTH SYSTEM
Feb 5, 2026 7:00pm – 7:00pm
Work Order: WO-01324678
Account: GE Healthcare FMI
Customer Case Number: 1-556702294951
Location: UNIVERSITY OF VIRGINIA HEALTH SYSTEM
Address: 1215 LEE ST, CHARLOTTESVILLE, VA 22908
Manufacturer: GE Healthcare
Model #: Giraffe OmniBed Carestation
Serial #: TABB71310
Contact Name: Matthew Frank
Cont
JPG
TABB71310_DOORS
Feb 6, 2026
JPG
TABB71310_SN
Feb 6, 2026
JPG
TABB71310_SCREW
Feb 6, 2026
PDF
UVA Medical FMI 32097 complete 2-6-2026
Feb 7, 2026
Timeline
📞
Case Linked Dec 9, 1:49 PM
Case Number:00550250
Subject:GE FMI 32097 - UVA
Status:Closed
📋
Work Order Created Dec 9, 5:56 PM
Work Order:WO-01324678
Type:FCO
Priority:PC
⏳4.8 business days
✅
Status: Ready for Release by Mandy NewmanDec 15, 12:19 PM